Details
Evaluation unit – Non-contact overhead wire contact
The type 8480-KAG2 evaluation unit is used for signal evaluation for the TLC 4 non-contact overhead wire contact. Both the isolating stage and the signal evaluation section are incorporated in a plastic housing.
Technical
data
|
Dimensions
|
WxHxD
150/73/113 mm
|
Housing material
|
Terminal
plate: Polycarbonate
|
|
Lower part: ABS
|
Attachment
|
Plastic-reinforced
glassfibre
|
Weight
|
approx.
1.4 kg
|
Attachment
|
2 holes to be drilled
as per the
drilling
|
|
template, standard carrying rail as
|
|
per DIN EN 50022
|
Type of protection
|
Housing:
IP 40; terminals: IP 10
|
Ambient temperature
|
-20°C to
+70°C
|
Supply voltage
|
terminal 31 (N/L-); terminal 32 (L/
|
|
L+)
|
|
AC 230 V ? 8480 1-
|
|
DC 18 V - 80 V ? 8480 5-
|
|
Special voltages on request
|
Current drawn
|
approx.
10 VA /5 W
|
Sensor connection
|
resistant
to short-circuits, terminal 21
|
|
(-); terminal 22 (+)
|
Open-circuit voltage:
|
DC 24 V± 5%
|
max. current
|
approx. 200 mA
|
Signal inputs:
|
2
antivalent inputs, terminals 19/20
|
max. current
|
< 35 mA (limited)
|
Input divider
|
1
input pulse = 1 output pulse
? 8480 11 / ? 8480 51
|
|
2 input pulses = 1 output pulse
|
|
? 8480 12 / ? 8480 52
|
Input memory
|
max. 15 (30) signal pulses can be stored
|
Relay outputs
|
2
changeover contacts (zero-
|
|
potential) terminals 11 - 16
|
|
Voltage Current cos ?
|
|
AC 250 V 4.0 A
> 0.7
|
|
DC 80 V 1.0
A ohmic load
|
Signal duration
|
0.6 s
(in the case of multiple signals,
|
|
breaks likewise 0.6 s), other timings
|
|
such as 0.5 s to special order
|
Error
|
1
changeover contact (zero-poten-
|
|
tial) terminals
4 - 6
|
|
Voltage Current cos ?
|
|
AC 250 V 4.0
A > 0.7
|
|
DC 80 V 1.0 A ohmic load
|
|
Can be switched between working
|
|
current and quiescent current
|
Ext.
acknowledgement
|
Remote
acknowledgment (and local)
|
|
terminals 8 - 9
|
Voltage at the
terminals
|
DC 15 V; 1k < 20 mA
|
Test voltage
|
4 kVeff
|