What are you looking for?

Dynisco 1390-2-3 Temperature Indicator

BRAND : Dynisco

  • 350 ohm strain gage input
  • Pushbutton programming and calibration
  • Configwareâ„¢ SW configurable
  • Scalable, voltage or current outputs
  • MODbus communication option
  • Peak and valley detection
  • Transducer interrupt detection
  • UL, cUL recognized
  • CE approved

    Specifications Performance Characteristics Instrument type: Digital panel meter Display: 5 red LED digits 0.5" (12.7mm) high 2 red LED lights for alarm 1 green LED light for remote configuration Accuracy: ±0.1% Normal Mode Reject...

Details

  • 350 ohm strain gage input
  • Pushbutton programming and calibration
  • Configwareâ„¢ SW configurable
  • Scalable, voltage or current outputs
  • MODbus communication option
  • Peak and valley detection
  • Transducer interrupt detection
  • UL, cUL recognized
  • CE approved

    Specifications Performance Characteristics Instrument type: Digital panel meter Display: 5 red LED digits 0.5" (12.7mm) high 2 red LED lights for alarm 1 green LED light for remote configuration Accuracy: ±0.1% Normal Mode Rejection Ratio: 60dB at 50/60Hz Sampling Time: 100mS Input Thermocouple: Types J, K, E, L, N, R, S, T RTD: Type PT100 (DIN 43760) Linear Input: 0(4)-20mA and 0(1)-5Vdc and 0(2)-10Vdc Scaling: ?F or ?C programmable Alarm Outputs (2) Alarm Type: Two SPST Form C Contact Rating: 0.6A @110Vdc, resistive load 0.5A @220Vdc, resistive load 0.3A @110Vdc, inductive load Alarm Update Time: 100mS Analog Retransmission Outputs Type: 0(4)-20mA, 0(1)-5V or 0(2)-10V. 500?, max load Resolution: ±0.05% of output span maximum Accuracy: ±0.2% of span Update Time: 100mS Serial Communication Interface Type: Isolated RS-485 Protocol: ModBus/JBus selectable (half duplex) Baud Rate: 150 – 19200 baud Format: 8 bits + parity; 8 bits without parity Parity: Odd / Even Mechanical & Packaging Characteristics Termination: Screw terminals on rear with safety covers Front Panel: IP65/NEMA4-rated with gasket Operating Temperatures: 32? – 130?F (0? – 55?C) Humidity: 5 – 85% relative humidity, non-condensing Vibration: 10 – 150Hz at a peak of 1G Approvals & Certifications CE Mark: EMC standard EN 61326-1 2002 Safety standard EN 61010-1 2001 Agency approvals: UL: According to UL 3121-1 cUL: According to C22.2 No. 142 C-Tick: Australia Power Supply (Mains) Input Power: 85-264 Vac (24V ac/dc available) Power Consumption: 10W, max Input Protection: Internal thermistor Isolation: Reinforced isolation from instrument and all other I/O circuits