What are you looking for?

Coax VMK / VFK 40 DR 3/2 Way Externally Controlled Coaxaial Valve

BRAND : Coax

Ports
VMK threads NPT 11/2 - NPT 2
VFK flanges ANSI 1500
Function
NC
Pressure Range

Details

Ports
VMK threads NPT 11/2 - NPT 2
VFK flanges ANSI 1500
Function
NC
Pressure Range
0-960 / 0-1500 psi
A ? B max. 1500 psi
B ? A max. 240 psi
A ? C max. 1500 psi
C ? A max. 1500 psi
cv Value
35.8 GPM
Media
gaseous, liquid, highly viscous, gelatinous, pasty, contaminated
Flow Direction
see pressure range
Switching Cycles
150 1/min
Switching Time [ms]
opening 100-3000 closing 100-3000
Media Temperature [°F]
direct mounted pilot valve 140
Ambient Temp. [°F]
direct mounted pilot valve 122
Weight [kg]
VMK 18,5 VFK 26,5
Nominal Voltage
UN DC 24V, UN AC 230V 50 Hz
Power Consumption
DC 4,8 W, AC pick up 11,0 VA holding 8,5 VA
Protection
IP 65 (P54) acc. DIN 40 050
Energized Duty Rating
ED 100%

Other Suggested Products

Products