Details
PortsMK threads NPT 11/2 - NPT 2
FK flanges ANSI 150 / 600 / 1500FunctionNCPressure Range0-240 / 0-600 / 0-960 psicv Value21.3 GPMMediagaseous, liquid, highly viscous, gelatinous, contaminatedFlow DirectionA ? B as markedSwitching Cycles90 1/minSwitching Time [ms]opening 520 closing 150Media Temperature [°F]DC: -4 to 212
AC: -4 to 212Ambient Temp. [°F]DC: -4 to 176
AC: -4 to 176Weight [kg]MK 14,0 FK 18,0Nominal VoltageUN 24 V DC, UN 230 V 40-60 Hz ACActuationDC direct-current magnet
AC direct-current magnet with integrated rectifierProtectionIP65Energized Duty RatingED 100%Connectionplug acc. DIN EN 175301-803 , form A, 4 positions x 90° / , wire diameter 6-8 mm