Range of measurement | 0 to 120° |
Sensitivity | 5 mV/° |
Transformer LVDT | Range = ±5.08 mm |
| Impedance, primary winding = 970 ohm/2500 Hz |
| Impedance, secondary windings = 1010 ohm/2500 Hz |
| Max linearity error = ± 0.5% f.s. |
| Nominal sensitivity = 63 mV/mm |
| Frequency range = 50 Hz to 10 kHz |
| Supply voltage = 3 V rms (rated) |
Range of application | Temperature = -55°C to +95°C |
| Humidity = max 95% not condensing |
| Vibrations = max 20 g / 2 KHz |
| Ambient = IP55 EN60529/10.90 standards |
Power supply | ± 15 Vdc, GND |
Connection | connector 7-pin MIL C-5015 series 3106/16, standard kit |
Outer casing material | Aluminium |
Weight | Kg 3 approx. |
Maintenance | none |