What are you looking for?

BUCHER WS22ONDB-10-1 24D Solenoid Directional Cartridge Valve

BRAND : BUCHER

With bidirectional seat-valve shut-off

No external pilot drain required

High flow rates

Version with return spring for main spool

All exposed parts with zinc-nickel plating

High pressure wet-armature solenoids

The slip-on coil can be rotated, and it can be

replaced without opening the hydraulic envelope

Various plug-connector systems and voltages

are available

Can be fitted in a line-mounting body

Can be fitted in sandwich bodies


General characteristics Description, value, unit

Designation 2/2 solenoid cartridge valve

Design bidirectional seat-valve shut-off, two-stage

Mounting method screw-in cartridge M24x1.5

Size nominal size 10, cavity type DD

or cavity type DC (option with adapter ring C)

Weight 0.52 kg

Mounting attitude unrestricted

Switching safety achieved by flow and ?p.
Hydraulic fluid HL and HLP mineral oil to DIN 51 524;
for other fluids, please contact BUCHER
Ambient temperature range 1) -25°C … +80°C
Hydraulic fluid temperature range 1) -25°C … +80°C 2)
Viscosity range 10…500mm2/s (cSt), recommended 15...250mm2/s (cSt)
Minimum fluid cleanliness
Cleanliness class to ISO 4406:1999
class 20/18/15
Electrical characteristics Description, value, unit
Supply voltage 12V DC, 24V DC
115V AC, 230V AC (50…60Hz)

Details

With bidirectional seat-valve shut-off

No external pilot drain required

High flow rates

Version with return spring for main spool

All exposed parts with zinc-nickel plating

High pressure wet-armature solenoids

The slip-on coil can be rotated, and it can be

replaced without opening the hydraulic envelope

Various plug-connector systems and voltages

are available

Can be fitted in a line-mounting body

Can be fitted in sandwich bodies


General characteristics Description, value, unit

Designation 2/2 solenoid cartridge valve

Design bidirectional seat-valve shut-off, two-stage

Mounting method screw-in cartridge M24x1.5

Size nominal size 10, cavity type DD

or cavity type DC (option with adapter ring C)

Weight 0.52 kg

Mounting attitude unrestricted

Switching safety achieved by flow and ?p.
Hydraulic fluid HL and HLP mineral oil to DIN 51 524;
for other fluids, please contact BUCHER
Ambient temperature range 1) -25°C … +80°C
Hydraulic fluid temperature range 1) -25°C … +80°C 2)
Viscosity range 10…500mm2/s (cSt), recommended 15...250mm2/s (cSt)
Minimum fluid cleanliness
Cleanliness class to ISO 4406:1999
class 20/18/15
Electrical characteristics Description, value, unit
Supply voltage 12V DC, 24V DC
115V AC, 230V AC (50…60Hz)
Supply voltage tolerance ±10%
Ambient temperature range 1) -25°C … +50°C
Nominal power consumption V DC = 27 W
V AC = 25 W
Relative duty cycle 100%
Protection class to ISO20653 / EN60529 IP 65 / IP 67 / IP 69K, see “Ordering code”
(with appropriate mating connector and
proper fitting and sealing)
Electrical connection DIN EN 175301-803, 3-pin 2 P+E (standard)
for other connectors, see “Ordering cod