What are you looking for?

Asco JSIS8314B300.24/DC 24v Dc Solenoid Valve

BRAND : Asco

Features

• Available in 4 different coil terminations

• H Class coil construction

• Designed solely for installation in intrinsically safe

or NIFW areas, with properly approved and sized

limiting barriers

• Compatible with supervisory current applications

• Mountable in any position

Electrical

Valve Parts in Contact with Fluids

Body Aluminum Brass Stainless Steel

Seals and Discs PUR, NBR

Sleeve 430 Stainless Steel

Core and Plugnut 430F Stainless Steel

Core Springs 302 Stainless Steel

Pilot Seat Insert (Series 8316 & 8344 only) POM

Rider Rings PTFE

Spring Retainer POM

Valve Construction

Enclosure Ratings

Rcoil - The resistance of the solenoid coil at

Tambient in degrees C

- Loop current in the circuit, which may be

calculated as follows:

= 320 ohms x (Tambient + 234)

254

Vsupply

(Rcoil + Rloop + Rbarrier) =

Iloop

Iloop

Rloop - Resistance of the lead wires

Rbarrier - Internal resistance of the barrier

- Supply voltage Vsupply

Where:

Rcoil

This current must always be greater than or equal to 0.030 amps

for proper operation of the solenoid valve.

Catalog

Prefix Description

Enclosure

Type Rating

Enclosure

IP Rating

IS 1/2" NPT Conduit 4, 4X IP66

6, 6P IP67

JPIS Aluminum Junction Box

with 1/2" NPT C...

Details

Features

• Available in 4 different coil terminations

• H Class coil construction

• Designed solely for installation in intrinsically safe

or NIFW areas, with properly approved and sized

limiting barriers

• Compatible with supervisory current applications

• Mountable in any position

Electrical

Valve Parts in Contact with Fluids

Body Aluminum Brass Stainless Steel

Seals and Discs PUR, NBR

Sleeve 430 Stainless Steel

Core and Plugnut 430F Stainless Steel

Core Springs 302 Stainless Steel

Pilot Seat Insert (Series 8316 & 8344 only) POM

Rider Rings PTFE

Spring Retainer POM

Valve Construction

Enclosure Ratings

Rcoil - The resistance of the solenoid coil at

Tambient in degrees C

- Loop current in the circuit, which may be

calculated as follows:

= 320 ohms x (Tambient + 234)

254

Vsupply

(Rcoil + Rloop + Rbarrier) =

Iloop

Iloop

Rloop - Resistance of the lead wires

Rbarrier - Internal resistance of the barrier

- Supply voltage Vsupply

Where:

Rcoil

This current must always be greater than or equal to 0.030 amps

for proper operation of the solenoid valve.

Catalog

Prefix Description

Enclosure

Type Rating

Enclosure

IP Rating

IS 1/2" NPT Conduit 4, 4X IP66

6, 6P IP67

JPIS Aluminum Junction Box

with 1/2" NPT Conduit

4, 4X IP66

6, 6P IP67

JSIS 316L Stainless Steel Junction Box

with 1/2" NPT Conduit

4, 4X IP66

6, 6P IP67

ISVT 5-Pin (Male M12) NA IP20

ISSC DIN (Form A) NA IP2