Aoip MF 28 Electrical Firing Unit on Pyrotechnical Elements

BRAND : Aoip

The firing units MF 28 are highly accurate current generators, programmable in amplitude and duration, specifically developed for use on pyrotechnical elements where user safety is at stake.

The MF 28 accurately control non-fire current as well as time and energy of activation. They can be used for instrumented, performance and product line tests (with process automation) on pyrotechnical elements.

Several protections are integrated into the instrument in order to guarantee a safe use in any critical environment and more particularly for pyrotechnical systems:

External safety input (do...

Details

The firing units MF 28 are highly accurate current generators, programmable in amplitude and duration, specifically developed for use on pyrotechnical elements where user safety is at stake.

The MF 28 accurately control non-fire current as well as time and energy of activation. They can be used for instrumented, performance and product line tests (with process automation) on pyrotechnical elements.

Several protections are integrated into the instrument in order to guarantee a safe use in any critical environment and more particularly for pyrotechnical systems:

External safety input (door closing, barrier closing, etc.)

Safety key extractible in "SAFETY" position

Protected "MANUAL" triggering button

Safety pyrotechnical ohmmeter at measurement current of < 10 mA, allowing continuity tests to be performed (to limit and control current, even in case of failure)

DC output line to prevent build-up of electrical charges

Further key elements in MF 28 design guarantee the accurate control of the ignition:

Absence of any overshoot

Rising time < 10 ?s at 1 A

Any potential residual discharges, inopportune firing causes, are automatically removed by automatic short-circuiting of shot-firing cables.

Technical features:

  • Programmable current from 1 to 10 A
  • Programmable timing
  • Embedded line pyrotechnical ohmmeter
  • Isolated floating shot firing cable
  • 5 protection elements
  • Load breakdown detection
  • Manual or automated triggers
  • 3 synchronisation outputs (zero time, crenel current, current image)
  • Optional remote control of the cycle SAFE AUTHORIZATION OF FIRE

Yearly calibration is highly recommended in order to control the safety functions of your firing unit.

Technical support:

  • Our technical staff can support you:
  • Commissioning of your MF 28
  • Management of units evolution (number and functional needs)
  • On site breakdown servicing
  • Unit integration on test bench
  • On site investigation of any measurement issues