Aoip CALYS 150 Field Instruments

BRAND : Aoip

CALYS 150 field documenting multifunction calibrator is the top instrument of the range. It is the perfect tool for advanced process maintenance and use on test bench in all industries. Suitable for all field and lab measurements, it can simultaneously measure and generate over two isolated channels various signals of temperature, resistance, process, pressure and frequency in one single instrument. CALYS 150 does not only work as a simulator (IN / OUT) but also as a dual channel thermometer (IN / IN) to perform comparison calibration. It calibrates HART transmitters (HART communicator integrated into ACL500 modem) and thermistors. Providing extended functionalities (temperature simulation, scaling, steps, synthesizer, statistical functions…) and audit trails, CALYS 150 complies with both 21 CFR Part 11 and NADCAP Heat Treatment standards and makes advanced...

Details

CALYS 150 field documenting multifunction calibrator is the top instrument of the range. It is the perfect tool for advanced process maintenance and use on test bench in all industries. Suitable for all field and lab measurements, it can simultaneously measure and generate over two isolated channels various signals of temperature, resistance, process, pressure and frequency in one single instrument. CALYS 150 does not only work as a simulator (IN / OUT) but also as a dual channel thermometer (IN / IN) to perform comparison calibration. It calibrates HART transmitters (HART communicator integrated into ACL500 modem) and thermistors. Providing extended functionalities (temperature simulation, scaling, steps, synthesizer, statistical functions…) and audit trails, CALYS 150 complies with both 21 CFR Part 11 and NADCAP Heat Treatment standards and makes advanced data exploitation and full data traceability easier. High performances for CALYS 150, for advanced use:

  • Temperature Up to 0.005 % RDG
  • Resistance Up to 0.006 % RDG and 50 K? range
  • Current: Up to 0.007 % RDG and 100 mA range + Loop Supply 24 V
  • Voltage: Up to 0.005 % RDG and 50 V range
  • Frequency: Up to 0.01 % RDG and 100 KHz range
  • Pressure: With an external pressure module (comparison calibration with a pressure pump)

Using this user-friendly instrument, calibration tasks can be quickly carried out over the whole process chain. Take the 900 g documenting process calibrator to the field with you during the whole week with 10 calibration procedures stored in the device. Run the procedure after connecting the probes to the instrument (Easy connect system®) and save the results for onsite easy and quick calibration. Back to the office, you can then upload the data on a computer in order to issue customized calibration certificates with dedicated calibration software DATACAL. IP 54, fully protected by an antichoc rubber holster, CALYS 150 integrates "easyconnect" terminals and a wide backlite display that makes it easy to use in any severe or dark conditions. When used with an external pressure module (ref. ACL433), CALYS 150 can measure and simulate pressure (comparison calibration with a pressure pump). CALYS 150 has also the capability to drive baths and dry-blocks when associated with the specific cable (ref. ACL600).

Easy connection system

CALYS_Easyconnect pressed_BD Connect your probes by simply pushing on the terminal top and insert wires of up to 3 mm or 10 AWG diameter and compensated thermocouple connectors. Wires are held tight between two brass plates ensuring thermal stability and a very good cold junction compensation for thermocouples. This system also enables 4 mm banana plugs and security connectors to be connected on the terminal top.


Specifications

CALYS 50

CALYS 75

CALYS 100

CALYS 150

Top accuracy

200 ppm

130 ppm

50 ppm

Temperature accuracy

Thermocouples (14) RTDs (12)

0.013% RDG for Tc K 0.012% RDG

0.01% RDG for Tc K 0.01% RDG

0.005% RDG for Tc K 0.006% RDG

DC current + Loop supply 24 V

Range Accuracy

50 mA 0.0175% RDG

100 mA 0.007% RDG

DC voltage

Range Accuracy

50 V IN / 20 V OUT 0.013% RDG

50 V 0.013% RDG

50 V 0.010% RDG

50 V 0.005% RDG

Frequency

Range Accuracy

20 KHz IN / 10 KHz OUT 0.005% RDG

100 KHz 0.01% RDG

Resistance

Range Accuracy

4000 ? 0.012% RDG

4000 ? 0.010% RDG

50 K? 0.006% RDG

Pressure

Range Accuracy

Relative pressure: 30 bar / Absolute pressure: 1,000 bar 0.05% RDG

Compliance to standards

21 CFR Part 11

NADCAP Heat treatment AMS 2750

Additional functions

Advanced data exploitation: Scaling, relative measurement, simulation of ramps and steps, synthetizer, square root, statistical functions Transmitter function

Additional functions

Switch test Calibration of transmitters

Additional functions

Comparison calibration HART: Digital calibration and data transfer Calibration of thermistors

Software

DATACAL calibration software for configuration and data management

Memory

10,000 data stored and recalled on screen as curve or list