Details
Large bore direct mount 2, 3 or 5 valve manifold system with renewable block valve metal or soft seats and graphite or PTFE stem packings that reduces potential leakpoints
- Close coupled straight through ?” (10 mm) bore to transmitter reduces gauge line error and enhances transmitter performance.
- Provides required spacing for installation via Sr. orifice changers with no need for spacer flanges or manifolds.
- Optional rating to Fire-Safe API 607.
- Two-piece modular Coplanar™ flange (Rosemount 305) elimination system provides permanent diaphragm protection during maintenance.
- No additional brackets or pipe support required.
- Direct mount system eliminates impulse lines and conventional root block valve block system.
- Post installation instrument retrofit capability.
- Mounts all manufacturers’ field instruments.
- Modular design enables system hydrotest and certification without instrument. Total installation, including transmitter, ships in one package to the field.