Details
The simplest and most effective means to install and calibrate Rosemount® Coplaner™ style transmitters
- Compact design reduces installation costs and potential leakage points.
- Process inlet and vent connections supplied G ¼” parallel threaded to DIN 3852 fitted with tube/compression fittings. ¼” NPT female option available.
- Suitable for liquid or gas service.
- Fully self draining.
- Equalize and vent valves fitted with an anti tamper facility.
- Choice of manifold configurations to suit the application: AS6 2/1 - Double isolate, equalize, vent AS6 2/2 - Double isolate, double vent AS6 2/3 - Single isolate, vent/ block AS6 2/5 - Single isolate, vent/ block (threaded connections).
- Designed to be generally compatible with Shell M.E.S.C specification 60.98.56. XXX
- NACE /sour gas service option available.
- Choice of accessories: Seal pot, filling connectors Heater (steam/electric) Mounting plate Sun shade